Hardness Tester

Tablet hardness testers are specifically designed to determine the mechanical integrity and breaking strength of solid dosage forms. By applying a controlled compressive load until the tablet fractures, these instruments provide critical data for assessing the structural strength required for tablets to withstand rigorous processes such as film coating, automated packaging, and global distribution.
Engineered for exceptional accuracy and repeatability, these systems feature high-precision load cells and motorized jaw drives, thereby eliminating the variability inherent in manual testing.

Hardness Tester

Product Display

No products found

Benefits

Exceptional Measurement Accuracy
Exceptional Measurement Accuracy

Utilizing high-sensitivity load cells and advanced digital signal processing technology, this device delivers highly precise readings of breaking force. This capability helps maintain the critical balance between a tablet being "hard enough to withstand handling" and "soft enough to disintegrate correctly."

Electric Linear Drive Ensures Repeatability
Electric Linear Drive Ensures Repeatability

The electric drive system applies pressure at a constant and controlled rate. This eliminates human error and ensures that the force application rate remains consistent across every sample, thereby providing reliable, statistically significant data for quality audits.

Multi-Parameter Testing Capability
Multi-Parameter Testing Capability

Modern hardness testers typically integrate "four-in-one" functionality, allowing for the simultaneous measurement of a tablet's hardness, thickness, diameter, and weight within a single automated test cycle. This significantly enhances laboratory workflow efficiency.

Convenient Calibration and Verification
Convenient Calibration and Verification

Designed for convenient on-site calibration, allowing users to perform the procedure using certified standard weights or electronic load cells. This ensures that the instrument consistently complies with GMP standards and provides reliable, digitally traceable records.

Exceptional Measurement Accuracy
Exceptional Measurement Accuracy

Utilizing high-sensitivity load cells and advanced digital signal processing technology, this device delivers highly precise readings of breaking force. This capability helps maintain the critical balance between a tablet being "hard enough to withstand handling" and "soft enough to disintegrate correctly."

Electric Linear Drive Ensures Repeatability
Electric Linear Drive Ensures Repeatability

The electric drive system applies pressure at a constant and controlled rate. This eliminates human error and ensures that the force application rate remains consistent across every sample, thereby providing reliable, statistically significant data for quality audits.

Multi-Parameter Testing Capability
Multi-Parameter Testing Capability

Modern hardness testers typically integrate "four-in-one" functionality, allowing for the simultaneous measurement of a tablet's hardness, thickness, diameter, and weight within a single automated test cycle. This significantly enhances laboratory workflow efficiency.

Convenient Calibration and Verification
Convenient Calibration and Verification

Designed for convenient on-site calibration, allowing users to perform the procedure using certified standard weights or electronic load cells. This ensures that the instrument consistently complies with GMP standards and provides reliable, digitally traceable records.

Application

Standard Round and Oblong Tablets
Standard Round and Oblong Tablets

Primarily used to measure the radial crushing strength of conventional oral medications, ensuring they do not chip or fracture during high-speed blister packaging processes.

Large Veterinary Boluses
Large Veterinary Boluses

Tested using specialized instruments equipped with high-capacity fixtures, designed for large-format animal medications; the crushing strength requirements for such drugs are significantly higher than those for tablets intended for human use.

Nutritional and Herbal Supplements
Nutritional and Herbal Supplements

Used to assess the structural integrity of various dietary supplements; as these products often contain fibrous or oily natural ingredients, achieving uniform and consistent compression during the tableting process can be challenging.

Extended-Release Tablets
Extended-Release Tablets

Applied to the "tablet core" prior to the coating stage. This test aims to ensure the core possesses sufficient strength to withstand abrasion or fracture while tumbling at high speeds and under elevated temperatures within the coating pan.

R&D Phase (Formulation and Process Optimization)
R&D Phase (Formulation and Process Optimization)

Crucial for researchers, as it facilitates the investigation of the intrinsic relationship between compression pressure and tablet hardness, thereby aiding in the determination of the optimal "dwell time" and compression parameters required for new drug formulations.

FAQ

What units are used to measure tablet hardness?

The most commonly used units include Newtons (N), Kiloponds (kp), or Strong-Cobb (Sc). Most modern digital testers allow users to switch between these units instantly via a settings menu.

The testing jaws are specifically designed to accommodate tablets of various shapes including round, oval, capsule-shaped, and even unique geometric forms by automatically centering the tablet to ensure that the applied force acts precisely along its diameter.

Although the specific range varies by product, the hardness of most standard oral tablets falls between 50 N and 150 N. Extended-release tablets may require higher hardness values, while chewable tablets typically have significantly lower hardness.

Yes. The faster the jaws move, the higher the measured hardness reading tends to be. For this reason, both USP (United States Pharmacopeia) and EP (European Pharmacopoeia) standards recommend using a constant loading rate to ensure that test results are comparable across different laboratories.

To ensure compliance with 21 CFR Part 11 regulations and GMP guidelines, it is recommended to perform a functional check daily and a comprehensive professional calibration using certified standard weights every 6 to 12 months.

Unlock Your Medicine Production Potential. Speak with an Innoval Pharma Expert to Tailor Your Solution.

Certificates

Related Products

45
44
43
42

Contact Info

Call Us

+1(323)215-9729 (North/South America)

Email

sales@innovalpharma.com

WhatsApp

+1(213)258-7721

After Service

+1(909)230-8253 (North/South America)

Get In Touch

*We respect your confidentiality, and all information is protected.

Scroll to Top

Get a Quote